| Technology | CET & RET Radiofrequency Energy Transfer |
| RF Frequency | 300 kHz / 448 kHz |
| Maximum Output Power | 300 W |
| Therapy Modes | CET & RET |
| Thermal Modes | Non-Thermal / Moderate Thermal / Deep Thermal |
| Treatment Tip Sizes | 20 / 40 / 60 mm |
| Display | 10.4-inch Touchscreen |
| Optional Applicators | D80 Applicator / T-Shaped Applicator / Fascia Tool Set / Foot Electrode Pad |
| Package Size | 500 × 450 × 370 mm |
| Package Weight | 15 kg |
| Packaging | Aluminum Flight Case |
| Main Unit Warranty | 2 Year |
| Accessory Warranty | 1 Year |
Smart Program
Smart preset programs provide clear treatment guidance and help practitioners operate the system more efficiently.
Real-Time Parameter Display
Three Progressive Biological Effects for Flexible Therapy
Multiple Body Area Selections
Preset Treatment Protocols for Each Area
Multiple Applicator Options
Designed for Different Treatment Areas
Three Progressive Thermal Effects
01 NON-THERMAL
Minimal noticeable heating
→ Sensitive / early-stage programs
02 THERMAL
Moderate endogenous heating
→ Circulation / muscle / soft tissue
03 DEEP THERMAL
Stronger endogenous thermal response
→ Chronic stiffness / deeper musculoskeletal applications
How TECAR Diathermy Works?
TECAR diathermy delivers radiofrequency energy through the target tissues between the active applicator and return electrode. As the RF energy interacts with tissue impedance, it is converted into controlled heat within the tissues, creating an endogenous thermal effect rather than simply heating the skin from the surface.
300 & 448 kHz Dual-Frequency TECAR Technology
Two frequencies provide greater flexibility for different tissue targets and treatment objectives. The system combines 300 kHz RET with 448 kHz CET, allowing practitioners to adapt TECAR therapy according to tissue characteristics, treatment depth and clinical goals.
300 kHz RET — Deeper Musculoskeletal Applications
Designed for higher-resistance tissues and deeper musculoskeletal areas, making it suitable for tendons, ligaments and joint-related structures.
448 kHz CET — Muscle & Soft Tissue Applications
Designed for water-rich and more superficial tissues, making it suitable for muscles, soft tissues and broader treatment areas.
Therapeutic Effects of TECAR Therapy
- Controlled Endogenous Heating– Generates controlled thermal effects within targeted tissues through radiofrequency energy.
- Local Circulation Support– Supports local blood flow and tissue circulation in the treated area.
- Muscle Relaxation– Helps relax tense muscles and reduce stiffness during rehabilitation.
- Soft Tissue Support– Supports soft tissue treatment and recovery as part of professional rehabilitation programs.
- Mobility Support– Helps address tissue stiffness and supports movement and flexibility.
- Pain Management Support– Supports professional pain management through controlled thermal effects, tissue treatment and muscle relaxation.
TECAR Therapy Applications for Pain Management & Rehabilitation
From muscle tension and joint discomfort to tendon, ligament and sports-related injuries, this TECAR system supports a wide range of professional pain management and musculoskeletal rehabilitation applications.
Pain Management
Helps relieve muscle, joint, and soft tissue discomfort.
Muscle Tension & Pain Relief
Helps relieve muscle tightness, trigger points and myofascial discomfort, promoting relaxation and muscle recovery.
Joint Pain & Mobility
Helps manage joint‑related discomfort, supports mobility and improves flexibility.
Tendon & Ligament Rehabilitation
Supports the recovery of tendons, ligaments and surrounding soft tissues from overuse or injury.
Sports Injuries & Recovery
Supports recovery from sports‑related muscle and soft tissue injuries, helping you return to activity.
Back Pain & Mobility
Supports the management of back pain, muscle tension and mobility issues, helping to improve comfort and function in daily activities.
Product Display
Accessories
Optional Accessories
D80 Applicator Designed for larger treatment areas and joint-related applications, including the shoulders, elbows, and knees.
T-Shaped Applicator Ideal for more targeted treatment around the spine, cervical area, and hands, providing greater flexibility for smaller or difficult-to-reach areas.
Fascia Tool Set Designed for neck, back, spine, and full-body soft tissue applications, making it a useful addition to manual and fascia-focused therapy programs.
Foot Electrode Pad Provides an additional hands-free electrode option for foot-based TECAR therapy, further expanding the system’s treatment configurations.
Who is it for?
- Physiotherapy Clinics
- Rehabilitation Centers
- Sports Medicine & Recovery Centers
- Chiropractic Clinics
- Pain Management Clinics
- Wellness & Physical Therapy Centers
Why Add Smart TECAR to Your Practice?
Expand Your Treatment Services
CET and RET radiofrequency therapy supports pain management, sports recovery, soft tissue therapy, and musculoskeletal rehabilitation, helping your practice serve a wider range of client needs.
One System Multiple Applications
Dual-frequency CET and RET modes, multiple treatment tips, and optional applicators allow one device to cover different body areas and therapy programs, reducing the need for multiple separate systems.
Improve Treatment Efficiency
Preset programs, body-area selection, and real-time parameter display simplify treatment setup, helping practitioners manage daily sessions more efficiently.
Low Ongoing Operating Costs
With no costly single-use treatment cartridges required for standard TECAR sessions, ongoing operating costs can remain relatively low, supporting stronger margins as treatment volume grows.
Contraindications
- Do not apply treatment to the eyes or surrounding areas, heart, spinal cord, gonads, kidneys, or liver.
- Not suitable for individuals with blood disorders, coagulation disorders, or those receiving anticoagulant therapy.
- Do not apply treatment over areas with polyps or abnormal tissue growths.
- Not suitable for individuals with thrombosis.
- Do not apply treatment over tumors or malignant areas.
- Not recommended for individuals with polyneuropathy or significant sensory impairment in the treatment area.
- Do not apply treatment over growth plates in children or adolescents who are still growing.
- Use caution in individuals receiving corticosteroid therapy.
- Avoid direct application over major nerve bundles, major blood vessels, the spinal cord, or the head.
FAQ
CET (Capacitive Energy Transfer) uses an insulated electrode and is primarily suited to water-rich tissues such as muscles and soft tissues. RET (Resistive Energy Transfer) uses a conductive electrode and is designed to work with higher-resistance tissues such as tendons, ligaments, and joint-related structures. Together, CET and RET allow practitioners to adapt TECAR therapy to different tissue types and treatment needs.
Yes. The system includes smart preset programs for different treatment areas, helping practitioners quickly select suitable parameters. Professional settings can also be adjusted according to individual treatment needs.
Yes. A suitable conductive cream should be applied during TECAR treatment to ensure proper energy transfer between the applicator and the skin while allowing the treatment head to move smoothly over the treatment area.