| Specification | MT-72 |
|---|---|
| Magnetic Induction Intensity | 6 T |
| Frequency | 1–100 Hz |
| Screen | 12.1″ Capacitive Touchscreen |
| Treatment Modes | Auto / Manual |
| Cooling | Air Cooling |
| Power | ≤1500 W |
| Net / Gross Weight | 22.5 / 33.5 kg |
| Package Size | 67 × 62 × 45.5 cm |
| Voltage | AC 220–240V / 50Hz; AC 110–130V / 60Hz |
Deep, Focused & Non-Contact Magnetic Stimulation for Professional Physiotherapy & Rehabilitation
Designed for physiotherapy clinics, rehabilitation centers and sports recovery facilities, this High Intensity PEMF Therapy Machine provides adjustable magnetic stimulation for professional muscle, nerve and musculoskeletal rehabilitation applications. With intensity up to 6 Tesla, stimulation depth up to 8 cm, adjustable 1–100 Hz frequency and non-contact operation, it combines powerful output with flexible treatment control.
Concentrate Magnetic Energy Around the Target Area
Unlike a wider magnetic field distribution, the specially designed figure-of-8 coil helps concentrate magnetic field lines around the target area, providing more focused stimulation when the applicator is positioned over a specific treatment region.
Powerful Output with Flexible Intensity Control
Adjust the magnetic stimulation intensity according to different treatment areas and therapy requirements, with stimulation strength reaching up to 6 Tesla. Combined with an adjustable frequency range of 1–100 Hz, the system gives professionals greater flexibility when setting treatment parameters for different applications.
Reach Beyond Superficial Treatment Areas
High-intensity magnetic stimulation can reach up to 8 cm beneath the skin, allowing stimulation of deeper muscle and nerve tissue beyond superficial treatment areas. This provides greater flexibility for professional applications involving different anatomical depths.
Product Features and Advantages
One System for Multiple Rehabilitation Needs
Designed for professional physiotherapy and rehabilitation, the system can be incorporated into programs involving muscles, joints, tendons, ligaments and peripheral nerve areas. Typical applications include muscle-related conditions, joint rehabilitation, shoulder and upper-limb applications, lumbar and thoracic areas, as well as Achilles tendon and ligament applications.
Flexible Treatment from Upper Body to Lower Limbs
Built-in treatment programs cover common body areas including the wrist, elbow, shoulder, cervical and lumbar regions, groin, hip, thigh, knee, and foot/ankle, allowing one system to support a wide range of professional treatment scenarios across the body.
Non-Contact Magnetic Stimulation
The system generates a time-varying magnetic field that induces electrical activity within excitable tissue. Unlike conventional electrical stimulation, magnetic stimulation does not require electrodes or direct contact with the skin, allowing the applicator to deliver stimulation through clothing.
Faster Setup with the Flexibility to Adjust
Choose from built-in body-area programs for faster treatment setup, or switch to manual control when more customized parameters are required. Adjustable treatment settings give professionals the flexibility to adapt stimulation according to different treatment areas and individual therapy requirements.
Position the Applicator Without Continuous Hand-Held Operation
The 360° telescopic positioning arm can be adjusted from multiple angles to hold the magnetic applicator over the target area. Once positioned, the applicator remains supported without continuous hand-held operation, making treatment positioning easier for everyday professional use.
A Flexible Addition to Different Rehabilitation Practices
The High Intensity PEMF Therapy Machine is designed for physiotherapy clinics, rehabilitation centers, sports recovery facilities and other professional musculoskeletal therapy settings looking to add non-contact magnetic stimulation to their existing services. Its adjustable parameters and multi-area treatment capability allow it to fit into different professional treatment workflows.
No Cooling Fluid Replacement or Leakage Concerns
The intelligent variable-frequency air-cooling system manages heat during operation without relying on liquid cooling, eliminating routine cooling-fluid replacement and avoiding the leakage concerns associated with liquid-based cooling systems.
A Smoother Transition in Stimulation Intensity
The progressive pulse design gradually increases stimulation intensity, maintains the selected high-intensity output, and then gradually decreases it, creating a smoother transition throughout the stimulation cycle.
Product Display
How to Use
Suggested Parameters
| Area | Energy | F1 | F2 | F3 |
|---|---|---|---|---|
| Wrist | 30 | 27 | 25 | 7 |
| Elbow | 30 | 27 | 25 | 7 |
| Shoulder | 50 | 31 | 29 | 9 |
| Groin | 45 | 26 | 22 | 6 |
| Hip | 60 | 31 | 29 | 10 |
| Thigh | 50 | 27 | 25 | 7 |
| Lumbar Vertebra | 50 | 31 | 28 | 8 |
| Cervical Vertebra | 50 | 27 | 25 | 7 |
| Knee | 55 | 31 | 29 | 9 |
| Foot/Ankle | 40 | 27 | 25 | 7 |
Thermal Imaging Results
Thermal imaging shows the effect before and after treatment. Due to muscleactivation and strong pulse magnetic field effects, itcan be seen significantlychanges in blood circulation, vascular diastolic and metabolism.
Contraindications
This therapy is not recommended for individuals with the following conditions or circumstances:
- Pregnancy or menstruation
- Electronic or metal implants in the treatment area
- Epilepsy
- Malignant tumors in the treatment area
- Within 3 weeks after surgery
- Pacemakers or severe cardiac arrhythmias
- Perceptual or cognitive impairment
Areas & Conditions to Avoid
Treatment should not be applied to or near the following areas or under the following conditions:
- Eyes and surrounding areas, myocardium, spinal cord, gonads, kidneys, or liver
- Blood disorders, coagulation disorders, or use of anticoagulant medication
- Polyps in the treatment area
- Thrombosis
- Tumors
- Polyneuropathy
- Growing cartilage in children
- Corticosteroid therapy
- Areas close to major nerve bundles, major blood vessels, the spinal cord, or the head